We carry many parts and supplies for evaporative coolers. Precisions new air cooled ceramic dual ball bearing. Coolair also produces ventilation and evaporative cooling systems for the poultry, swine, dairy, greenhouse and golf industries. You can use it as a dependable replacement in a coolers spider bearing. All of vortecs enclosure coolers keep electrical and electronic enclosures cool, clean and protected and are a low cost alternative to expensive, high maintenance air conditioners. Cooling system optimization cooling best practices. When economy is measured in terms of cubic feet of air per minute per dollar invested, the type nbf wall exhaust fan is unsurpassed. This evaporative cooling design guidelines manual for new mexico schools and. Open the cover of the electrical control box if furnished located on the unit.
Evaporative cooler parts bearings indoor comfort supply. Step 1 turn off the water at the shut off valve for the swamp cooler and flip the power switch off for the cooler. Types pv150pv600 fit easily in briefcase, toolbox or glove. Used on fractional hp motors with low to moderate loads. In this type of cooling tower the transfer of heat takes place through a surface which separates the working fluid from ambient air, such as in a tube to air heat exchanger, utilizing convective heat transfer. Dual, angular contact ceramic ball bearings are utilized for maximum durability and an increased thrust load. The bearings are often found behind pieces of the cooler which have rusted or become damaged, so this can make it a difficult task for an amateur. Between these bearings allow two solid smooth surface, low friction motion. Servicing evaporative coolers pmi uses a sintered bronze bearing on the blower assembly. Evaporative cooler bearing maintenance ball bearings. It is recommended that all nuts and set screws be tightened. A dual ball bearing design ensures reliability and longer life this versatile 12cm pc case fan is designed to fit a broad range of computer case designs, to circulate cool air into the case, or exhaust warm air out preventing problems due to overheating components. Unfasten the bolts on the top of the bearing housings on both ends of the drive shaft with a socket wrench, and take the hold down brackets off the top of the bearings. It is the same principle by which an air fan cools you as it evaporates perspiration from your skin.
Despite all the fans suffering premature bearing failure at one time or another, there were in. Being the market leader and number one in natural cooling, breezair is the quietest running and most energyefficient product on the market. Commercialmedical linear power supply, 100120240 vac input voltage types pv150 and pv375 include a cigarette lighter plug and replaceable external fuses. A wide variety of fan bearing types options are available to you, such as single row. The parts of an evaporative cooler are all designed to facilitate efficient evaporation of water and circulation of the cooled air. Ball bearing fan diagram sleeve bearing fans are also very common. They have 2 ball bearing bearings, had all the mounting holes in exactly the right place, and it took me about 5 minutes to open up the pc case and replace the two bad fans.
Cooling tower products is arizonas leading manufacturer and direct supplier of cooling tower parts and products for all types and brands of cooling tower needs. Vortec vortex ac enclosure cooler and hazardous location duty class 1, div 2. Some bac factory authorized parts are also suitable for use in other manufacturers products. Its better to start your order with trade assurance to get full protection for your samples order.
This closedloop system was designed for cooling highspeed bearings in the manufacturing of yarn used in tires. The basics of case fan bearings which bearing is best. Oil the blower wheel bearings on both sides of the rotating shaft. This is the standard equation for all ball and roller bearings. The bronze bearing is surrounded by a permawick felt that holds the oil. The cooling fans are installed vertically underneath, blasting air upward into the coolers. How to replace the bearings of an evaporative cooler ehow.
Step 3 slide the old bearings off both ends of the drive shaft, and remove them from the evaporative cooler. Ball bearing and sleeve bearing fans pelonis technologies. Only use one of the following greases, as they are compatible with the grease installed at the factory. Induced draft products lubricate the bearings at least every three months. Ball and cushion bearing for evaporative coolers 6692, bearing steel bearing features a 34 in. These units feature an aircooled, ball bearing center housing rotating assembly. Next you will have to take out the old ball bearings. May 2016 cooling system design cooling best practices. There are no moving parts, the bearing ball bearing. These units require the use of a 18 npt to 4 an male fitting on the oil feed side, which can be purchased separately from precision turbo pft0473039. Bacs parts are manufactured to meet rigorous cooling tower duty specifications and are guaranteed to fit your unit and perform as original equipment. Prior to startup and during the first week of operation, the bearing oil cup must be refilled with an industrialtype mineral oil to saturate the wick in the bearing reservoir. What are the hot models of deep groove ball bearings we can supply9 bearing no. Neoprene or bunan 0rings and seals are common, with a wide variety of optional elastomers for special applications.
Traditional compressor designs have separation systems to separate out the oil mixed with the refrigerant so that the oil can be used as a bearing lubricant. The international bearing community also has an association to regulate. Ball bearings sph erical roller bearings t a p ered roller bearings t h r u s t bearings sp li t p illo w bloc k s s u p er p recision bearings rolling m ill bearings l inear m o t ion e ngineering sec t ion 11 ball bearing applications general ball bearing applications are listed below. Yet, when the ambient temperatures were relatively low, sleeve bearing fans lasted as long as ball bearing fans. Roche molecular solutions operates two 756ton cooling towers and three ammonia chillers totaling 1,600 tons.
Step 1 turn off the water at the shut off valve for the swamp cooler and flip the power switch off for the cooler at the breaker box before attempting to grease the bearings. With such a sitemap, its much easier for the crawlers to see the complete structure of your site and retrieve it more efficiently. Evaporative cooling design guidelines cedengineering. They use lubricated sleeve surfaces which can be selflubricating. Provide manual reset control for motors rated greater than 34 kw one. Evapco midland sales provides a comprehensive parts and service program for all brands of existing evaporative cooling equipment.
Turn fan shaft by hand to make certain that blower does not rub against blower housing, and that bearing set screws are tight. Recommended spec for ball bearing operating temperature is below 70c80c. Fan shaft bearing maintenance cooling towers, closed. These fans have an average life span of 70,000 hours which figures out to be about 8 years of continuous run time. American coolairs type nbf fan is todays best investment. The larger cooling capacity units address the need for reduced sound, high efficiency and low maintenance while advancing the future of chillers. Ball bearing fans can be mounted in any axial orientation without concern for degradation of. Each bearing type has certain characteristics which make it suitable for a.
Cooling tower world is the only place to purchase bac factory authorized parts online. They have a long lifespan, many lasting over 60,000 hours. Todays small, compact multifunction electronic controls, variable. Evaporative cooler bearing ball6693 the home depot. Evaporation of the base oil should be prevented by design. They are also more durable at higher temperatures and fairly quiet at high speeds. When warm, dry unsaturated air is pulled through a watersoaked pad, water is evaporated and is absorbed as water vapor into the air. As evaporator coolers tend to easily rust and corrode swamp cooler parts, you may find that you need to repair and replace the cooler bearings every so often. American coolair products are fabricated in a 210,000 sq. Course contents evaporative coolers, often called swamp coolers, are cooling systems that use only water and a blower to circulate air. Greasing the bearings of the swamp cooler takes only a few minutes and will keep this evaporative cooling machine running properly.
The 20 or 30 weight non detergent oil then permeates thru the bearings microscopic pores onto the blower shaft. Shaft seal designs are of the conventional mechanical types, with single, double, and wet and dry tandem arrangements usually available. Eventually everything fails, and even ball bearings have their limitations. Evaporative swamp cooler parts, pads, covers and mastercool pads and pumps. The commonest evaporative coolers are essentially cubical metal or plastic boxes with large flat vertical air. There are two main types of bearings used in axial fans. Bearing life calculation factors the equation for calculating the life of a rolling contact bearing is as follows. Coolair uses only the most efficient totally enclosed ball bearing motors available. Mounted ball bearings, certain series mounted roller bearings, and spherical. There are 685 suppliers who sells fan bearing types on, mainly located in asia. Ul classified evaporative cooler replacement pumps. Cooling tower parts marley bac cooling tower products. The wheel type of such centrifugal fans is often called squirrel cage wheel.
In the majority of cooler, oil bearing is a very simple work. How to grease the bearings of a swamp cooler hunker. Each ventilation system and accessory is crafted with quality. Since these are used in numerous applications, we cannot. The oil must be resistant to oxidation, gumming and evaporation so that viscosity assumes. L103000cp n500s l10 is the life in hours that 90% of the bearings are expected to endure. Recirculating oil lubrication with additional cooling is particularly. Evaporative cooling design guidelines manual iv this report by nrg engineering is funded by the new mexico energy minerals and natural resources department, 1220 south st. These highspeed bearings required a new, thinner, cooling medium that has different heat transfer properties. In order to mitigate biocontamination on wet surfaces of the closed loop evaporative cooling towers, engineers decided to employ a dynamic water uet water treatment process using controlled partial electrolysis. Both have advantages and disadvantages all of which should be considered in the design application phase. Servicing evaporative coolers evaporative air cooling. Bearing type bearings support the rotating parts of the motor. Boca bearings is the leader in ceramic and ceramic hybrid bearing technology for industrial and recreational applications.
Japan nsk deep groove ball bearing 6202z for evaporative cooler pictures. We provide our customers with all type of indigenous roller bearings with world class quality. With its patented technology and use of inverter technology. Specializing in mastercool coolers and air conditioning parts and supplies. There are long banks of these coolers arranged as cells in an elevated steelwork structure. Ball bearing fans are the most common as they are simple and effective. Can canadian estimated usd us ball bearing units are designed to operate inside the harsh environment of evaporative cooling equipment. Evaporative cooler bearing ball6692 the home depot. We offer replacement cooling tower parts for marley, bac, evapco, tower tech, recold, imeco, vilter and frigid coil cooling towers. Most of the residential and small commercial model, bronze bearing. Oil bearing regular oiling, check the evaporative cooler or swamp cooler bearing can save a major headache and costs for you.
Therefore, if an application generates high levels of heat, an engineer may want to use a ball bearing fan. Maintenance, training programs, unit inspections, service, equipment upgrades, replacement parts and replacement units are all services provided. Types of evaporative cooling equipment are described in the ashrae. Datasheets on the bearing series can be generated as pdf files. Evaporative coolers, often known as swamp coolers, work by extremely simple physics. Optional manual control for cool pump and fan only and 248 hour timer mode. They do not use evaporation technique, so the consumption of makeup water is very less. Its accepted that ball bearings produce more noise then sleeve bearings 1 to 3 dba according to some sources but the differences are rarely noticeable during their typical roles in cooling fans. We are committed to keeping all of your equipment running at peak performance through the life of the unit by providing. This fluid is also much more expensive then more typical, glycol or. Evaporative cooling design guidelines ced engineering. As water evaporates, it effectively consumes heat from the surrounding air. Since refrigerants are typically very good solvents, it is difficult to avoid dilution of the oil by the refrigerant.
238 271 1180 1436 1528 33 1430 127 260 964 902 994 1388 1136 7 1436 753 386 1099 1060 1221 1399 947 1295 1250 618 971 1376 1420 1200 1066 417